Technical Specifications
Roll Size
- 30 m x 1mtr wide x 8mm thick
- 22 m x 1350 wide x 8mm thick
Packaging
- Appx 17kgs weight per roll , 1m x 700 dia rolls.
- DS= Metallic film both sides
- Also available SS= Metallic film one side, other side white foam
Service temperatures
- Max temp (continuous) 90 degrees Celsius
- Min temp minus 40 degrees Celsius
Noise Reduction
- Sound Transmission Class STC 12
Accessories
- Foil Joining Tape Reinforced 48 mm
- Self Adhesive AS1530.3 x 50mtr roll
- Foil Joining Tape Reinforced 72mm
- Self Adhesive AS1530.3 x 50mtr roll
- Timber Fix Clips Bag 125 clips
- E-Pin Insulation Bag 100 sets
- Spike & Washer 50mm
- Self adhesive
- FX-10 Primer Spray 150g Can
- E-Spacer 42mm Bag 100 pcs Bag
- Thick Foam
Manufacturing standards
Manufactured standard
- AS/NZS 4859.1:2002 "Materials for the thermal insulation of buildings".
Fire Tests
- AS/NZS 1530.3 "Simultaneous determination of Ignitability, flame propogation, heat release and smoke release."
- AS/NZS 3837-1998 (Group 1 rating) "Method of Test for Heat and Smoke Release rates for Materials and Products using an Oxygen Consumption Calorimeter"
- AS 1530.2-1993 " Methods for fire tests on building materials, components and structures - Test for flammability of materials"
- BS6853:1999 "Area based toxic fume test used in the design and construction of Passenger carrying Trains"
Emmissivity
ASTM E 408-71 " Standard test methods for total normal emmitance of surfaces using inspection-meter techniques"
Airborne sound transmission loss
AS1191 : 2002 "Method for laboratory measurement of airborne sound transmission loss of building partitions."
How to Specify E-Therm In your project: E-Therm Specification
The insulation shall be E-Therm tm distributed by DMS Industries.
Material shall be closed cell direct extruded (100% recyclable grade) polyethylene foam, having a density of not less than 25kg/m 3 , and shall incorporate metallic film on both sides.
The E-Therm insulation shall have a thickness of not less than 8mm and a surface emittance of 0.06 when tested to ASTM Standard E408-71.
The insulation and reinforced foil tape shall have a early fire hazard test result Index of four zeros (0) when tested in accordance with AS/NZS 1530.3.
All insulation shall be installed as tightly as possible without gaps. The edges and ends shall be tightly butted together. Butt joints shall be taped using a (48mm or 72mm wide) delete as required adhesive backed PVC tape.
Where necessary, the material shall be cut (using a sharp knife or scissors) and butt joined, to ensure a tight fit against adjoining walls and surfaces. Airgaps will be minimised and sealed with reinforced foil tape at all times.
Additional protective measures may be required for areas where the product is subject to mechanical damage.
If supports are encountered when insulation is installed near mechanical and electrical components such as pipe work, cables, ventilation ducting etc, the insulation shall be butted tightly up to these and sealed using reinforced foil tape.
Manufacturer's written instructions and fastening accessories will be used when installing E-Therm insulation.